Appearance
Connectors
Some systems keep records your registers need but do not send them: they must be asked. A connector asks them, on a timetable, and keeps the register up to date: a sensor platform's homes, alarms, readings and alerts, for example. Packs bring connectors, switched off. Nothing is read until you give a connector the sign-in details its supplier gave you and switch it on.
Systems that can send records themselves use the public API instead, and need no connector.
You need the permission to manage integrations.
Switching one on
Go to Admin, then Connectors, and choose the connector.
- Tick Read from this system.
- Enter the Client id and Secret (or API key) the supplier gave you. The secret is kept encrypted and never shown again; leave it blank later to keep it.
- Choose Save.
Saving signs in straight away, so a wrong client id or secret is said there and then.
What it reads
What it reads lists the connector's feeds: what each reads, where it goes, how often, when it last read and what happened. Each feed is read on its own timetable, such as alerts every 15 minutes and homes once a day. Read now reads every feed straight away.
- A feed that fails, such as when the supplier's service is down, says why and is tried again at its next time.
- Items that cannot be taken in, such as a row missing something the register requires, are counted, with the first problem. The rest are taken in.
- If the supplier refuses the sign-in, the connector stops and says so at the top of the page. Put the details right and save to start it again.
What a connector reads goes through the same checks as a change made on screen. Entries and rows are matched on the other system's own identifier, so reading the same records again changes what is there rather than adding copies. A connector can leave alone what an entry already there holds for its own reasons, as HomeLINK leaves a home's name and kind. Readings already held are not taken in twice. Changes appear in each entry's history, and readings and alerts show the connector as their source.
Connectors that read files
Some systems cannot be asked and do not send records one at a time: they export files, such as an HR system's daily organisation, employee and absence files. A connector can read those files instead. Its page is laid out differently:
- Tick Switched on: read the files that arrive.
- Under Where the files come from, choose:
- Sent to this system: the other system sends each file to the public API (
POST /api/v1/connectors/{key}/files, with an API client allowed to change register entries), or you upload one under Files received. - Fetched from our SFTP server: give the SFTP server, the User to sign in as and the Folder. Saving makes the connector's SSH key: give its public key to whoever looks after the server, to add to the user's authorised keys, then switch the connector on. A Password can be used instead, if the server takes no keys. Switching it on signs in at once, and trusts the server's host key from then on: a server with a different key is refused until you tick Forget it and trust the server's key next time.
- Sent to this system: the other system sends each file to the public API (
- Tick Files are encrypted with OpenPGP if they are. Saving makes the connector's key pair; give the other system the public key (download it, or copy it from the page) to encrypt files to. A file that is not encrypted is then refused. Paste the sender's OpenPGP public key as well to have every file checked as signed by them.
- If your files' column headings are not the ones the connector reads, give your own under your files' column headings, for each feed.
- Choose Save.
Each feed reads the files whose names match its pattern, such as Employee*.csv (an encrypted file is matched without its .pgp, .gpg or .asc). Files are read within a minute of arriving, in the order the connector lists its feeds, so units are in before the employees in them. Files on an SFTP server are looked for as often as the feed says, and each is fetched once.
Files received lists the last 50, newest first: where each came from, and what reading it did (rows added, changed, unchanged, archived, made current again, and not taken in, with the first problems by row). A file is kept as it came for 30 days, then removed; the record of reading it stays.
How a file is read:
- Nothing that has not changed is written. A daily file of 40,000 employees with a dozen changes changes a dozen entries, each with its history.
- A detail naming another entry can find it by that entry's own identifier, such as a line manager by their employee number, even when the manager comes later in the same file.
- A complete file holds every entry: entries it leaves out are archived, such as leavers, and an archived entry a later file holds is made current again. A file that would archive more than 10% of the current entries at once archives none, and says so, in case it was cut short.
- Values are read as a spreadsheet import reads them: dates as
2026-03-31or31/03/2026, yes and no, choices by their label or value. - Who is above whom in the organisation (see Registers) is worked out again as soon as a file changes anything.
A file that cannot be decrypted, is not signed by the sender, or is not laid out as the feed expects is not read at all, and says why.
Connectors from packs
The pack decides what a connector reads and where it goes: its addresses and how each reply is read. When the supplier changes their service, the pack's next version changes the connector, and your sign-in details and whether it is on are kept.
- Building safety brings AICO HomeLINK (see Building safety).
- Employee relations brings HR system files (see Employee relations).
A system with no connector in a pack can have one written for it, as a pack of your own (see Packs), from the supplier's API documentation. NEC Housing, for example, gives its API documentation to customers under contract, so it has no connector here: write one from that documentation, or have NEC's integration send records through the public API.